  ? semiconductor components industries, llc, 2012 september, 2012 ? rev. 2 1 publication order number: NCT210/d NCT210 low cost microprocessor system temperature monitor microcomputer the NCT210 is a two-channel digital thermometer and under/overtemperature alarm, intended for use in personal computers and other systems requiring thermal monitoring and management. the device can measure the temperature of a microprocessor using a diode-connected pnp transistor, which can be provided on-chip with the processor, or can be a low cost discrete npn/pnp device, such as the 2n3904/2n3906. a novel measurement technique cancels out the absolute value of the transistor?s base emitter voltage so that no calibration is required. the second measurement channel measures the output of an on-chip temperature sensor to monitor the temperature of the device and its environment. the NCT210 communicates over a two-wire serial interface compatible with smbus standards. under/overtemperature limits can be programmed into the device over the serial bus, and an alert output signals when the on-chip or remote temperature is out of range. this output can be used as an interrupt or as an smbus alert. features ? alternative to the adm1021a ? on-chip and remote temperature sensing ? no calibration necessary ? 1 c accuracy for on-chip sensor ? 3 c accuracy for remote sensor ? programmable over/undertemperature limits ? programmable conversion rate ? 2-wire smbus serial interface ? supports system management bus (smbus) alert ? 200  a max operating current ? 1  a standby current ? 3.0  v to 5.5  v supply ? small 16-lead qsop package ? this device is pb-free, halogen free and is rohs compliant applications ? desktop computers ? notebook computers ? smart batteries ? industrial controllers ? telecom equipment ? instrumentation http://onsemi.com see detailed ordering and shipping information in the package dimensions section on page 14 of this data sheet. ordering information marking diagram pin assignment qsop ? 16 case 492 sclk nc stby nc sdata add0 nc alert nc v dd d+ d ? nc add1 gnd gnd 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 NCT210 nc = no connect (top view) NCT210 = specific device code # = pb-free package yyww = date code NCT210 #yyww
NCT210 http://onsemi.com 2 figure 1. functional block diagram on-chip temperature sensor analog mux busy a-to-d converter local temperature value register run/standby external diode open-circuit status register smbus interface interrupt masking add0 add1 6 10 convertion rate register local temperature low limit register local temperature high limit register remote temperature low limit register remote temperature high limit register configuration register gnd 7 v dd 2 NCT210 d+ alert 3 d ? 4 remote temperature value register one-shot register sclk 14 sdata 12 15 stby address pointer register local temperature low limit comparator local temperature high limit comparator remote temperature low limit comparator remote temperature high limit comparator 11 nc 1 nc 5 gnd 8 nc 9 nc 13 nc 16 nc = no connect table 1. pin assignment pin no. mnemonic description 1 nc no connect 2 v dd positive supply, 3.0 v to 5.5 v 3 d+ positive connection to remote temperature sensor 4 d ? negative connection to remote temperature sensor 5 nc no connect 6 add1 three-state logic input, higher bit of device address 7 gnd supply 0 v connection 8 gnd supply 0 v connection 9 nc no connect 10 add0 three-state logic input, lower bit of device address 11 alert open-drain logic output used as interrupt or smbus alert 12 sdata logic input/output, smbus serial data. open-drain output 13 nc no connect 14 sclk logic input, smbus serial clock 15 stby logic input selecting normal operation (high) or standby mode (low) 16 nc no connect
NCT210 http://onsemi.com 3 table 2. absolute maximum ratings parameter rating unit positive supply voltage (v dd ) to gnd ? 0.3 to +6.0 v d+, add0, add1 ? 0.3 to v dd +0.3 v d ? to gnd ? 0.3 to +0.6 sclk, sdata, alert , stby ? 0.3 to +6.0 v input current 50 ma input current, d ? 1 ma esd rating, all pins (human body model) 2,000 v continuous power dissipation up to 70 c derating above 70 c 650 6.7 mw mw/ c operating temperature range ? 55 to +125 c maximum junction temperature (t j max ) 150 c storage temperature range ? 65 to +150 c lead temperature, soldering (10 sec) 300 c ir reflow peak temperature 220 c stresses exceeding maximum ratings may damage the device. maximum ratings are stress ratings only. functional operation above t he recommended operating conditions is not implied. extended exposure to stresses above the recommended operating conditions may af fect device reliability. note: this device is esd sensitive. use standard esd precautions when handling. table 3. thermal characteristics package type  ja unit 16-lead qsop package 105 c/w table 4. electrical characteristics (t a =t min to t max , v dd = 3.0 v to 3.6 v, unless otherwise noted) (note 1) parameter test conditions/comments min typ max unit power supply and adc temperature resolution guaranteed no missed codes 1.0 ? ? c temperature error, local sensor ? 3.0 1.0 +3.0 c temperature error, remote sensor t a =60 c to 100 c ? 3.0 ? 5.0 ? ? +3.0 +5.0 c supply voltage range (note 2) 3.0 ? 3.6 v undervoltage lockout threshold v dd input, disables adc, rising edge 2.5 2.7 2.95 v undervoltage lockout hysteresis ? 25 ? mv power-on reset threshold v dd , falling edge (note 3) 0.885 1.7 2.2 v por threshold hysteresis ? 50 ? mv standby supply current v dd = 3.3 v, no smbus activity sclk at 10 khz ? ? 1.0 4.0 5.0 ?  a average operating supply current 0.25 conversions/sec rate ? 130 200  a auto-convert mode, averaged over 4 sec 2 conversions/sec rate ? 225 370  a conversion time from stop bit to conversion complete (both channels) d+ forced to d ? + 0.65 v 65 115 170 ms remote sensor source current high level (note 3) low level (note 3) 120 7.0 205 12 300 16  a d ? source voltage ? 0.7 ? v address pin bias current (add0, add1) momentary at power-on reset ? 50 ?  a
NCT210 http://onsemi.com 4 table 4. electrical characteristics (continued) (t a =t min to t max , v dd = 3.0 v to 3.6 v, unless otherwise noted) (note 1) parameter unit max typ min test conditions/comments smbus interface (see figure 2) logic input high voltage, v ih stby , sclk, sdata v dd = 3.0 v to 5.5 v 2.2 ? ? v logic input low voltage, v il stby , sclk, sdata v dd = 3.0 v to 5.5 v ? ? 0.8 v smbus output low sink current sdata forced to 0.6 v 6.0 ? ? ma alert output low sink current alert f orced to 0.4 v 1.0 ? ? ma logic input current, i ih , i il ? 1.0 ? +1.0  a smbus input capacitance, sclk, sdata ? 5.0 ? pf smbus clock frequency ? ? 100 khz smbus clock low time, t low t low between 10% points 4.7 ? ?  s smbus clock high time, t high t high between 90% points 4.0 ? ?  s smbus start condition setup time, t su:sta 4.7 ? ?  s smbus repeat start condition 250 ? ? ns setup time, t su:sta between 90% and 90% points 250 ? ? ns smbus start condition hold time, t hd:sta time from 10% of sdata to 90% of sclk 4.0 ? ?  s smbus stop condition setup time, t su:sto time from 90% of sclk to 10% of sdata 4.0 ? ?  s smbus data valid to sclk time for 10% or 90% of sdata to 10% of sclk 250 ? ? ns rising edge time, t su:dat time for 10% or 90% of sdata to 10% of sclk 250 ? ? ns smbus data hold time, t buf:dat 0 ? ?  s smbus bus free time, t buf between start/stop condition 4.7 ? ?  s sclk falling edge to sdata ? ? 1  s valid time, t vd:dat master clocking in data ? ? 1  s 1. t max = 100 c, t min =0 c 2. operation at v dd = 5.0 v guaranteed by design; not production tested. 3. guaranteed by design; not production tested. figure 2. serial bus timing stop start t su; dat t high t f t hd; dat t r t low t su; sto stop start sclk sdata t buf t hd; sta t hd; sta t su; sta
NCT210 http://onsemi.com 5 typical performance characteristics figure 3. temperature error vs. pc board track resistance figure 4. temperature error vs. power supply noise frequency figure 5. temperature error vs. common-mode noise frequency figure 6. temperature error vs. capacitance between d+ and d ? figure 7. standby supply current vs. clock frequency leakage resistance (m  ) 1 temperature error ( c) ? 30 d+ to v dd d+ to gnd 10 100 ? 25 ? 20 ? 10 15 20 0 5 ? 15 ? 5 10 frequency (hz) 100 temperature error ( c) 0 250 mv p-p remote 1k 10k 100k 1m 10m 100m 1 2 3 4 5 100 mv p-p remote frequency (hz) 1 temperature error ( c) 0 100 mv p-p 10 100 1k 10k 100k 1m 10m 100m 0 1 2 3 4 5 6 7 8 9 50 mv p-p 25 mv p-p capacitance (nf) 2 temperature error ( c) ? 2 4 6 8 1012141618202224 0 2 4 6 8 10 12 14 sclk frequency (khz) 1 supply current (  a) 0 5 10 25 50 75 100 250 500 750 1000 10 20 30 40 50 60 70 figure 8. temperature error vs. differential-mode noise frequency frequency (hz) 100k temperature error ( c) 0 10 mv p-p v dd = 3.3 v v dd = 5 v 1 2 3 4 1m 10m 100m 1g
NCT210 http://onsemi.com 6 typical performance characteristics (cont?d) figure 9. operating supply current vs. conversion rate figure 10. standby supply current vs. supply voltage figure 11. response to thermal shock convertion rate (hz) 0.0625 50 supply current (  a) 3.3 v 0.125 0.25 0.5 1 2 4 8 100 150 200 250 300 350 400 450 500 550 5 v supply voltage (v) 0 ? 20 supply current (  a) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 0 20 40 60 80 100 time (s) 0 0 temperature ( c) remote tepmerature 12345678910 25 50 75 100 125 int tepmerature
NCT210 http://onsemi.com 7 functional description the NCT210 contains a two-channel a-to-d converter with special input-signal conditioning to enable operation with remote and on-chip diode temperature sensors. when the NCT210 is operating normally, the a-to-d converter operates in free-running mode. the analog input multiplexer alternately selects either the on-chip temperature sensor to measure its local temperature or the remote temperature sensor. these signals are digitized by the adc and the results stored in the local and remote temperature value registers as 8-bit, twos complement words. the measurement results are compared with local and remote, high and low temperature limits, stored in four on-chip registers. out-of-limit comparisons generate flags that are stored in the status register, and one or more out-of-limit results will cause the alert output to pull low. the limit registers can be programmed and the device controlled and configured via the serial system management bus (smbus). the contents of any register can also be read back via the smbus. control and configuration functions consist of: ? switching the device between normal operation and standby mode ? masking or enabling the alert output ? selecting the conversion rate on initial powerup, the remote and local temperature values default to ?128 c. since the device normally powers up converting, a measurement of local and remote temperature is made, and these values are then stored before a comparison with the stored limits is made. however, if the part is powered up in standby mode (stby pin pulled low), no new values are written to the register before a comparison is made. as a result, both rlow and llow are tripped in the status register, thus generating an alert output. this can be cleared in one of two ways. 1. change both the local and remote lower limits to ?128 c and read the status register (which in turn clears the alert output). 2. take the part out of standby and read the status register (which in turn clears the alert output). this works only if the measured values are within the limit values. measurement method a simple method of measuring temperature is to exploit the negative temperature coefficient of a diode, or the base-emitter voltage of a transistor, operated at constant current. unfortunately, this technique requires calibration to null the effect of the absolute value of v be, which varies from device to device. the technique used in the NCT210 is to measure the change in v be when the device is operated at two different currents. this is given by: (eq. 1)  v be  kt  q  1n ( n ) where: k is boltzmann?s constant. q is the charge on the electron (1.6 10 ?19 coulombs). t is the absolute temperature in kelvins. n is the ratio of the two currents. figure 12 shows the input signal conditioning used to measure the output of an external temperature sensor. this figure shows the external sensor as a substrate transistor provided for temperature monitoring on some microprocessors, but it could be a discrete transistor. if a discrete transistor is used, the collector will not be grounded and should be linked to the base. to prevent ground noise interfering with the measurement, the more negative terminal of the sensor is not referenced to ground, but is biased above ground by an internal diode at the d? input. if the sensor is operating in a noisy environment, one can optionally be added as a noise filter. its value is typically 2,200 pf, but it should be no more than 3,000 pf. see the layout considerations section for more information. to measure  v be , the sensor is switched between operating currents of i and n i. the resulting waveform is passed through a 65 khz low-pass filter to remove noise, and then to a chopper-stabilized amplifier that performs the functions of amplification and rectification of the waveform to produce a dc voltage proportional to  v be . this voltage is measured by the adc to give a temperature output in 8-bit, twos complement format. to reduce the effects of noise further, digital filtering is performed by averaging the results of 16 measurement cycles. signal conditioning and measurement of the internal temperature sensor is performed in a similar manner. figure 12. input signal conditioning low-pass filter f c = 65 khz remote sensing transistor bias diode d+ d ? v dd i bias in i v out+ v out ? to adc c1* *capacitor c1 is optional. it is only necessary in noisy environments. c1 = 2.2 nf typ, 3 nf max
NCT210 http://onsemi.com 8 temperature data format one lsb of the adc corresponds to 1 c so the adc can theoretically measure from ? 128 c to +127 c, although the device does not measure temperatures below ? 65 c; therefore, the actual range is ? 65 c to 127 c. the temperature data format is shown in table 5. the results of the local and remote temperature measurements are stored in the local and remote temperature value registers and are compared with limits programmed into the local and remote high and low limit registers. table 5. temperature data format temperature (  c) digital output ? 65 1 011 1111 ? 55 1 100 1001 ? 25 1 110 0111 0 0 000 0000 1 0 000 0001 10 0 000 1010 25 0 001 1001 50 0 011 0010 75 0 100 1011 100 0 110 0100 125 0 111 1101 127 0 111 1111 registers the NCT210 contains nine registers that are used to store the results of remote and local temperature measurements, and high and low temperature limits, and to configure and control the device. a description of these registers follows, and further details are given in table 6 to table 8. it should be noted that the NCT210?s registers are dual port and have different addresses for read and write operations. attempting to write to a read address, or to read from a write address, produces an invalid result. register addresses above 0x0f are reserved for future use or used for factory test purposes and should not be written to. address pointer register the address pointer register does not have and does not require an address, because it is the register to which the first data byte of every write operation is written automatically. this data byte is an address pointer that sets up one of the other registers for the second byte of the write operation or for a subsequent read operation. value registers the NCT210 has two registers to store the results of local and remote temperature measurements. these registers are written to by the adc and can only be read over the smbus. status register bit 7 of the status register indicates when it is high that the adc is busy converting. bit 5 to bit 3 are flags that indicate the results of the limit comparisons. if the local and/or remote temperature measurement is above the corresponding high temperature limit or below the corresponding low temperature limit, then one or more of these flags are set. bit 2 is a flag that is set if the remote temperature sensor is open-circuit. these five flags are nor?d together so that if any of them are high, the alert interrupt latch is set and the alert output goes low. reading the status register clears the fi ve flag bits, provided the error conditions that caused the flags to be set have gone away. while a limit comparator is tripped due to a value register containing an out-of-limit measurement, or the sensor is open-circuit, the corresponding flag bit cannot be reset. a flag bit can only be reset if the corresponding value register contains an in-limit measurement, or the sensor is good. table 6. status register bit assignments bit name function 7 busy 1 when adc converting 6 lhigh* 1 when local high temp limit tripped 5 llow* 1 when local low temp limit tripped 4 rhigh* 1 when remote high temp limit tripped 3 rlow* 1 when remote low temp limit tripped 2 open* 1 when remote sensor open-circuit 1 to 0 reserved *these flags stay high until the status register is read or they are reset by por.
NCT210 http://onsemi.com 9 table 7. list of NCT210 registers read address (hex) write address (hex) name power-on default not applicable not applicable address pointer undefined 00 not applicable local temperature value 1000 0000 (0x80) ( ? 128 c) 01 not applicable remote temperature value 1000 0000 (0x80) ( ? 128 c) 02 not applicable status undefined 03 09 configuration 0000 0000 (0x00) 04 0a conversion rate 0000 0010 (0x02) 05 0b local temperature high limit 0111 1111 (0x7f) (+127 c) 06 0c local temperature low limit 1100 1001 (0xc9) ( ? 55 c) 07 0d remote temperature high limit 0111 1111 (0x7f) (+127 c) 08 0e remote temperature low limit 1100 1001 (0xc9) ( ? 55 c) not applicable 0f (note 1) one-shot 10 not applicable reserved reserved for future versions 12 12 reserved reserved for future versions 13 13 reserved reserved for future versions 14 14 reserved reserved for future versions 15 16 reserved reserved for future versions 17 18 reserved reserved for future versions 19 not applicable reserved reserved for future versions 20 21 reserved reserved for future versions fe not applicable manufacturer device id 0100 0001 (0x41) ff not applicable die revision code 0011 xxxx (0x3x) 1. writing to address 0f causes the NCT210 to perform a single measurement. it is not a data register and data written to it is i rrelevant. the alert interrupt latch is not reset by reading the status register, but is reset when the alert output is serviced by the master reading the device address, provided the error condition has gone away and the status register flag bits have been reset. configuration register two bits of the configuration register are used. if bit 6 is 0, which is the power-on default, the device is in operating mode with the adc converting. if bit 6 is set to 1, the device is in standby mode and the adc does not convert. standby mode can also be selected by taking the stby pin low. in standby mode, the values stored in the remote and local temperature registers remain at the values they were when the part was placed in standby. bit 7 of the configuration register is used to mask the alert output. if bit 7 is 0, which is the power-on default, the alert output is enabled. if bit 7 is set to 1, the alert output is disabled. table 8. configuration register bit assignments bit name function power-on default 7 mask1 0 = alert enabled 1 = alert masked 0 6 run /stop 0 = run 1 = standby 0 5 to 0 reserved 0 conversion rate register the lowest three bits of this register are used to program the conversion rate by dividing the adc clock by 1, 2, 4, 8, 16, 32, 64, or 128 to give conversion times from 125 ms (code 0x07) to 16 seconds (code 0x00). this register can be written to and read back over the smbus. the higher five bits of this register are unused and must be set to 0. use of slower conversion times greatly reduces the device power consumption, as shown in table 9.
NCT210 http://onsemi.com 10 table 9. conversion rate register code data conversion/ sec average supply current  a typ at v cc = 3.3 v 0x00 0.0625 150 0x01 0.125 150 0x02 0.25 150 0x03 0.5 150 0x04 1 150 0x05 2 150 0x06 4 160 0x07 8 180 0x08 to 0xff reserved ? limit registers the NCT210 has four limit registers to store local and remote and high and low temperature limits. these registers can be written to and read back over the smbus. the high limit registers perform a > comparison, while the low limit registers perform a < comparison. for example, if the high limit register is programmed as a limit of 80 c, measuring 81 c results in an alarm condition. one-shot register the one-shot register is used to initiate a single conversion and comparison cycle when the NCT210 is in standby mode, after which the device returns to standby. this is not a data register as such, and it is the write operation that causes the one-shot conversion. the data written to this address is irrelevant and is not stored. serial bus interface control of the NCT210 is carried out via the serial bus. the NCT210 is connected to this bus as a slave device, under the control of a master device. note that the smbus and scl pins are three-stated when the NCT210 is powered down and will not pull down the smbus. address pins in general, every smbus device has a 7-bit device address (except for some devices that have extended 10-bit addresses). when the master device sends a device address over the bus, the slave device with that address responds. the NCT210 has two address pins, add0 and add1, to allow selection of the device address so that several NCT210?s can be used on the same bus, and/or to avoid conflict with other devices. although only two address pins are provided, these are three-state and can be grounded, left unconnected, or tied to v dd so that a total of nine different addresses are possible, as shown in table 10. it should be noted that the state of the address pins is only sampled at powerup, so changing them after powerup has no effect. table 10. device addresses (note 1) add0 add1 device address 0 0 0011 000 0 nc 0011 001 0 1 0011 010 nc 0 0101 001 nc nc 0101 010 nc 1 0101 011 1 0 1001 100 1 nc 1001 101 1 1 1001 110 1. add0 and add1 are sampled at powerup only. the serial bus protocol operates as follows: 1. the master initiates data transfer by establishing a start condition, defined as a high-to-low transition on the serial data line sdata, while the serial clock line sclk remains high. this indicates that an address/data stream will follow. all slave peripherals connected to the serial bus respond to the start condition and shift in the next eight bits, consisting of a 7-bit address (msb first) plus an r/w bit, which determines the direction of the data transfer, that is, whether data will be written to or read from the slave device. the peripheral whose address corresponds to the transmitted address responds by pulling the data line low during the low period before the ninth clock pulse, known as the acknowledge bit. all other devices on the bus now remain idle while the selected device waits for data to be read from or written to it. if the r/w bit is a 0, the master writes to the slave device. if the r/w bit is a 1, the master reads from the slave device. 2. data is sent over the serial bus in sequences of nine clock pulses, eight bits of data followed by an acknowledge bit from the slave device. transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, because a low-to-high transition when the clock is high can be interpreted as a stop signal. the number of data bytes that can be transmitted over the serial bus in a single read or write operation is limited only by what the master and slave devices can handle. 3. when all data bytes have been read or written, stop conditions are established. in write mode, the master pulls the data line high during the 10th clock pulse to assert a stop condition. in read mode, the master device overrides the acknowledge bit by pulling the data line high during the low period before the ninth clock pulse. this is known as no acknowledge. the master then takes the data line low during the low period
NCT210 http://onsemi.com 11 before the 10th clock pulse, then high during the 10th clock pulse to assert a stop condition. any number of bytes of data can be transferred over the serial bus in one operation, but it is not possible to mix read and write in one operation, because the type of operation is determined at the beginning and cannot subsequently be changed without starting a new operation. for the NCT210, write operations contain either one or two bytes, while read operations contain one byte. to write data to one of the device data registers or read data from it, the address pointer register must be set so that the correct data register is addressed, data can then be written into that register or read from it. the first byte of a write operation always contains a valid address that is stored in the address pointer register. if data is to be written to the device, the write operation contains a second data byte that is written to the register selected by the address pointer register. this is illustrated in figure 13. the device address is sent over the bus followed by r/w set to 0. this is followed by two data bytes. the first data byte is the address of the internal data register to be written to, which is stored in the address pointer register. the second data byte is the data to be written to the internal data register. figure 13. writing a register address to the address pointer register, then writing data to the selected register a6 sclk sdata a5 a4 a3 a2 a1 a0 d7 d6 d5 d4 d3 d2 d1 d0 ack. by NCT210 start by master 19 1 ack. by NCT210 9 d7 d6 d5 d4 d3 d2 d1 d0 ack. by NCT210 stop by master 1 9 sclk (continued) sdata (continued) frame 1 serial bus address byte frame 2 address pointer register byte frame 3 data byte r/w figure 14. writing to the address pointer register only a6 sclk sdata a5 a4 a3 a2 a1 a0 d7 d6 d5 d4 d3 d2 d1 d0 ack. by NCT210 stop by master start by master frame 1 serial bus address byte frame 2 address pointer register byte 1 1 9 ack. by NCT210 9 r/w figure 15. reading data from a previously selected register a6 sclk sdata a5 a4 a3 a2 a1 a0 d7 d6 d5 d4 d3 d2 d1 d0 no ack. by master stop by master start by master frame 1 serial bus address byte frame 2 data byte from NCT210 1 1 9 ack. by NCT210 9 r/w when reading data from a register there are two possibilities: 1. if the NCT210?s address pointer register value is unknown or not the desired value, it is first necessary to set it to the correct value before data can be read from the desired data register. this is done by performing a write to the NCT210 as before, but only the data byte containing the register read address is sent, because data is not to be written to the register. this is shown in figure 14. a read operation is then performed consisting of the serial bus address, r/w bit set to 1, followed
NCT210 http://onsemi.com 12 by the data byte read from the data register. this is shown in figure 15. 2. if the address pointer register is known to be already at the desired address, data can be read from the corresponding data register without first writing to the address pointer register, so figure 14 can be omitted. notes:although it is possible to read a data byte from a data register without first writing to the address pointer register, if the address pointer register is already at the correct value, it is not possible to write data to a register without writing to the address pointer register; this is because the first data byte of a write is always written to the address pointer register. remember that the NCT210 registers have different addresses for read and write operations. the write address of a register must be written to the address pointer if data is to be written to that register, but it is not possible to read data from that address. the read address of a register must be written to the address pointer before data can be read from that register. alert output the alert output goes low whenever an out-of-limit measurement is detected, or if the remote temperature sensor is open-circuit. it is an open drain and requires a 10 k  pullup to v dd . several alert outputs can be wire-anded together so the common line goes low if one or more of the alert outputs goes low. the alert output can be used as an interrupt signal to a processor, or it can be used as an smbalert . slave devices on the smbus cannot normally signal to the master that they want to talk, but the smbalert function allows them to do so. one or more alert outputs are connected to a common smbalert line connected to the master. when the smbalert line is pulled low by one of the devices, the following procedure occurs, as shown in figure 16. figure 16. use of smbalert alert response address master sends ara and read command device sends its address rd start ack device address no ack stop master receives smbalert 1. smbalert is pulled low. 2. master initiates a read operation and sends the alert response address (ara = 0001 100). this is a general call address that must not be used as a specific device address. 3. the device whose alert output is low responds to the alert response address and the master reads its device address. the address of the device is now known and it can be interrogated in the usual way. 4. if more than one device?s alert output is low, the one with the lowest device address has priority, in accordance with normal smbus arbitration. 5. once the NCT210 has responded to the alert response address, it resets its alert output, provided that the error condition that caused the alert no longer exists. if the smbalert line remains low, the master sends the ara again, and so on until all devices whose alert outputs were low have responded. low power standby modes the NCT210 can be put into a low power standby mode using hardware or software, that is, by taking the stby input low, or by setting bit 6 of the configuration register. when stby is high or bit 6 is low, the NCT210 operates normally. when stby is pulled low or bit 6 is high, the adc is inhibited, so any conversion in progress is terminated without writing the result to the corresponding value register. the smbus is still enabled. power consumption in the standby mode is reduced to less than 10  a if there is no smbus activity or 100  a if there are clock and data signals on the bus. these two modes are similar but not identical. when stby is low, conversions are completely inhibited. when bit 6 is set but stby is high, a one-shot conversion of both channels can be initiated by writing 0xxx to the one-shot register (address 0x0f). sensor fault detection the NCT210 has a fault detector at the d+ input that detects if the external sensor diode is open-circuit. this is a simple voltage comparator that trips if the voltage at d+ exceeds v cc ? 1.0 v (typical). the output of this comparator is checked when a conversion is initiated and sets bit 2 of the status register if a fault is detected. in this respect, the NCT210 differs from and improves upon competitive devices that output 0 if the external sensor goes short-circuit. these devices can misinterpret a genuine 0 c measurement as a fault condition. if the external diode channel is not being used and is shorted out, the resulting alert can be cleared by writing 0x80 ( ? 128 c) to the low limit register. factors affecting accuracy remote sensing diode the NCT210 is designed to work with substrate transistors built into processors, or with discrete transistors. substrate transistors are generally pnp types with the collector connected to the substrate. discrete types can be either pnp or npn, connected as a diode (base shorted to collector). if an npn transistor is used, the collector and base are connected to d+ and the emitter to d ? . if a pnp transistor is used, the collector and base are connected to d ? and the emitter to d+. the user has no choice in the case of substrate transistors, but if a discrete transistor is used, the best accuracy is
NCT210 http://onsemi.com 13 obtained by choosing devices according to the following criteria: 1. base-emitter voltage greater than 0.25 v at 6  a, at the highest operating temperature. 2. base-emitter voltage less than 0.95 v at 100  a, at the lowest operating temperature. 3. base resistance less than 100  . 4. small variation in h fe (such as 50 to 150), which indicates tight control of v be characteristics. transistors, such as 2n3904, 2n3906, or equivalents, in sot ? 23 package are suitable devices to use. thermal inertia and self-heating accuracy depends on the temperature of the remote-sensing diode and/or the internal temperature sensor being at the same temperature as that being measured, and a number of factors can affect this. ideally, the sensor should be in good thermal contact with the part of the system being measured, for example the processo r. if it is not, the thermal inertia caused by the mass of the sensor causes a lag in the response of the sensor to a temperature change. for the remote sensor, this should not be a problem, because it is either a substrate transistor in the processor or a small package device, such as sot ? 23, placed in close proximity to it. the on-chip sensor is, however, often remote from the processor and only monitors the general ambient temperature around the package. the thermal time constant of the qsop ? 16 package is approximately 10 seconds. in practice, the package will have an electrical, and hence a thermal, connection to the printed circuit board, so the temperature rise due to self-heating is negligible. layout considerations digital boards can be electrically noisy environments, and because the NCT210 is measuring very small voltages from the remote sensor, care must be taken to minimize noise induced at the sensor inputs. the following precautions should be taken: 1. place the NCT210 as close as possible to the remote sensing diode. provided that the worst noise sources, such as clock generators, data/address buses, and crts, are avoided, this distance can be four to eight inches. 2. route the d+ and d ? tracks close together, in parallel, with grounded guard tracks on each side. provide a ground plane under the tracks, if possible. 3. use wide tracks to minimize inductance and reduce noise pickup. 10 mil track minimum width and spacing is recommended. 4. try to minimize the number of copper/solder joints, which can cause thermocouple effects. where copper/solder joints are used, ensure they are in both the d+ and d ? paths and at the same temperature. thermocouple effects should not be a major problem as 1 c corresponds to about 240  v, and thermocouple voltages are about 3  v/ c of temperature difference. unless there are two thermocouples with a big temperature differential between them, thermocouple voltages should be much less than 240  v. 5. place a 0.1  f bypass capacitor close to the v dd pin, and 2,200 pf input filter capacitors across d+, d ? close to the NCT210. 6. if the distance to the remote sensor is more than eight inches, the use of twisted pair cable is recommended. this works up to about 6 to 12 feet. 7. for very long distances (up to 100 feet), use shielded twisted pair, such as belden #8451 microphone cable. connect the twisted pair to d+ and d ? and the shield to gnd close to the NCT210. leave the remote end of the shield unconnected to avoid ground loops. figure 17. arrangement of signal tracks 10 mil 10 mil 10 mil 10 mil 10 mil 10 mil 10 mil gnd d ? d+ gnd because the measurement technique uses switched current sources, excessive cable and/or filter capacitance can affect the measurement. when using long cables, the filter capacitor can be reduced or removed. cable resistance can also introduce errors. a series resistance of 1  introduces about 1 c error. application circuits figure 18 shows a typical application circuit for the NCT210, using a discrete sensor transistor connected via a shielded, twisted pair cable. the pullups on sclk, sdata, and alert are required only if they are not already provided elsewhere in the system. the sclk and sdata pins of the NCT210 can be interfaced directly to the smbus of an i/o chip. figure 19 shows how the NCT210 might be integrated into a system using this type of i/o controller.
NCT210 http://onsemi.com 14 figure 18. typical application circuit to control chip 3.3 v all 10 k  0.1  f gnd 2n3904 NCT210 sclk sdata alert v dd d ? d+ add1 add0 stby set to required address shield c1* in out i/o * c1 is optional figure 19. typical system using NCT210 fwh (fireware hub) cd ? rom pci bus smbus ich i/o controller hub gmch processor display display cache system memory super i/o system bus pci slots 2 usb ports 2 ide ports hard disk usb usb d ? d+ NCT210 sclk sdata alert table 11. ordering information device number package type package option shipping ? NCT210rqr2g 16-lead qsop rq 2,500 tape & reel ?for information on tape and reel specifications, including part orientation and tape sizes, please refer to our tape and reel packaging specifications brochure, brd8011/d.
NCT210 http://onsemi.com 15 package dimensions qsop16 case 492 issue a e m 0.25 c a1 a2 c detail a detail a h x 45  dim max min inches a 0.053 0.069 b 0.008 0.012 l 0.016 0.050 e 0.025 bsc h 0.009 0.020 c 0.007 0.010 a1 0.004 0.010 m 0 8 notes: 1. dimensioning and tolerancing per asme y14.5m, 1994. 2. controlling dimension: millimeters. 3. dimension b does not include dambar protrusion. 4. dimension d does not include mold flash, protrusions, or gate burrs. mold flash, protrusions, or gate burrs shall not ex- ceed 0.005 per side. dimension e1 does not include interlead flash or protrusion. in- terlead flash or protrusion shall not ex- ceed 0.005 per side. d and e1 are determined at datum h. 5. datums a and b are determined at datum h.  b l 6.40 16x 0.42 16x 1.12 0.635 dimensions: millimeters 16 pitch soldering footprint* 9 18 d d 16x seating plane 0.10 c e1 a a-b d 0.20 c e 18 16 9 16x c m d 0.193 bsc e 0.237 bsc e1 0.154 bsc l2 0.010 bsc d 0.25 c d b 0.20 c d 2x 2x 2x 10 tips 0.10 c h gauge plane c a2 0.049 ---- 1.35 1.75 0.20 0.30 0.40 1.27 0.635 bsc 0.22 0.50 0.19 0.25 0.10 0.25 0 8  4.89 bsc 6.00 bsc 3.90 bsc 0.25 bsc 1.24 ---- max min millimeters l2 a seating plane *for a dditional information on our pb-free strategy and soldering details, please download the on semiconductor soldering and mounting techniques reference manual, solderrm/d. on semiconductor and are registered trademarks of semiconductor co mponents industries, llc (scillc). scillc owns the rights to a numb er of patents, trademarks, copyrights, trade secrets, and other intellectual property. a list ing of scillc?s product/patent coverage may be accessed at ww w.onsemi.com/site/pdf/patent ? marking.pdf. scillc reserves the right to make changes without further notice to any products herein. scillc makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does scillc assume any liability arising out of the application or use of any product or circuit, and s pecifically disclaims any and all liability, including without limitation special, consequential or incidental damages. ?typical? parameters which may be provided in scillc data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. all operating parame ters, including ?typicals? must be validated for each customer application by customer?s technical experts. scillc does not convey any license under its patent rights nor the right s of others. scillc products are not designed, intended, or a uthorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in whic h the failure of the scillc product could create a situation where personal injury or death may occur. should buyer purchase or us e scillc products for any such unintended or unauthorized appli cation, buyer shall indemnify and hold scillc and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unin tended or unauthorized use, even if such claim alleges that scil lc was negligent regarding the design or manufacture of the part. scillc is an equal opportunity/affirmative action employer. this literature is subject to all applicable copyrig ht laws and is not for resale in any manner. publication ordering information n. american technical support : 800 ? 282 ? 9855 toll free usa/canada europe, middle east and africa technical support: phone: 421 33 790 2910 japan customer focus center phone: 81 ? 3 ? 5817 ? 1050 NCT210/d literature fulfillment : literature distribution center for on semiconductor p.o. box 5163, denver, colorado 80217 usa phone : 303 ? 675 ? 2175 or 800 ? 344 ? 3860 toll free usa/canada fax : 303 ? 675 ? 2176 or 800 ? 344 ? 3867 toll free usa/canada email : orderlit@onsemi.com on semiconductor website : www.onsemi.com order literature : http://www.onsemi.com/orderlit for additional information, please contact your local sales representative
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: on semiconductor: ? NCT210rqr2g


▲Up To Search▲   

 
Price & Availability of NCT210

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X